CL-2006 CHLORINE METER
Free chlorine and Total chlorine measurement
CHLORINE METER
Model : CL-2006 ISO-9001, CE, IEC1010
FEATURES
* The meter measures the Free and Total chlorine ( CL ) in the 0.00 to 3.50 ppm ( mg/L ). |
* The measuring method is an adaptation of the USEPA Method 330.5 for waste water and Standard Method 4500-Cl G for drinking water. |
* The advanced optical system based on a special narrow band LED lamp that allows most accurate and repeatable reading. |
* Friendly and powerful calibration function are able to validate good performance of your meter at any time. |
* 1.00 ppm Free standard solution and 1.00 ppm Total standard solution are includes as the standard accessories. |
* The unique optics structure, enables the instrument to read with high resolution : 0.01 ppm ( mg/L ). |
* Splash waterproof on the front panel. |
* Jumbo LCD, easy readout. |
* Microprocessor circuit assures maximum possible accuracy, provides special functions and features. |
* Battery operated for field and on-site testing convenience. |
* Data hold function for freezing the desired value on display. |
* Records Maximum and Minimum reading with Recall. |
* Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation. |
* Auto shut off is available to save battery life. |
* Application : Test swimming pool, municipal water, food and beverage water, or other aqueous solution where fluid clarity is important. |
SPECIFICATIONS
Circuit | Custom one-chip of microprocessor LSI circuit. | |
Display | LCD size : 41 mm x 34 mm | |
Range | Free chlorine ( CL ) : 0.00 to 3.50 ppm ( mg/L ). | |
Total chlorine ( CL ) : 0.00 to 3.50 ppm ( mg/L ). | ||
Resolution | 0.01 ppm ( mg/L ). | |
Accuracy | ± 0.02 ppm ( mg/L ). @ 1.00 ppm ( mg/L ) | |
Light source | LED, 525 nm. | |
Light detector | Photo diode | |
Response time | Less than 10 seconds. | |
Sample volume | 10 mL. | |
Data Hold | Freeze the display reading. | |
Memory Recall | Maximum & Minimum value. | |
Method | The measuring method is an adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. * The reaction between free ( total ) chlorine and the DPD reagent cause a pink tint in the sample. | |
Display Sampling Time | Approx. 1 second. | |
Power off | Auto shut off saves battery life or manual off by push button. | |
Calibration points | Zero chlorine. 1.00ppm ( Free chlorine ). 1.00ppm ( Total chlorine ). | |
Operating Temperature | 0 to 50 ℃. | |
Operating Humidity | Less than 85% R.H. | |
Power Supply | DC 1.5 V battery ( UM4, AAA ) x 6 PCs, or equivalent. | |
Power Current | Stand by | Approx. DC 4 mA. |
Testing | Approx. DC 12 mA. | |
Weight | 320 g/0.70 LB. @ Battery is included. | |
Dimension | 155 x 76 x 62 mm ( 6.1 x 3.0 x 2.4 inch) | |
Accessories Included | *Hard carrying case, CA-08................1 PC *Instruction manual...........................1 PC *1.0 ppm Free Chlorine standard solution, CF-01.................................1 PC *1.0 ppm Total Chlorine standard solution, CT-01................................1 PC *Zero Chlorine standard solution, CL-01..............................................1 PC *Empty testing bottle.........................2 PCs *Clean cloth.......................................1 PC *Free Chlorine DPD powder................10 PCs *Total Chlorine DPD powder...............10 PCs | |
Optional Accessories | *Free Chlorine DPD powder ( 10 PCs ), Model : CFP-10 *Total Chlorine DPD powder ( 10 PCs ), Model : CTP-10 *Empty testing bottle, Model : 0601 *1.0 ppm Free Chlorine standard solution, Model : CF-01 *1.0 ppm Total Chlorine standard solution, Model : CT-01 *Zero Chlorine standard solution, Model : CL-01 |