CM-6155C Smart 1000 A + max hold + Temp CAT III 1000 V CAT IV 600 V DCA/ACA CLAMP METER

Smart, 1,000 A, + max. hold, + Temp.
CAT III 1,000 V, CAT IV 600 V
DCA/ACA CLAMP METER
Model : CM-6155C      ISO-9001, CE, IEC1010

8179e72229ea2c34869c79083003ff66.png

b5c438d91c7950c4af948157cb0d01f2.png

FEATURES

* Meet IEC 1010 CAT III 1000 V safety requirement.

* 6000 counts A/D, high resolution.

* ACV, ACA, DCV, DCA, ohms, continuity, Hz, Capacitance, Diode, Temperature.

* Smart function, Auto range or manual range with hold.

* Smart operation, Build in 4 intelligent function : " V ", " Ω "," 600A ", " 1000A ".

* V " function can select ACV, DCV automatically with auto range.

* " Ω " function can select the Resistance , Diode, Continuity beeper, Capacitance automatically with auto range.

* " 600A " & " 1000A " function can select ACA, DCA automatically.

* Data hold .

* Auto shut off is available to save battery life.

* 10 M ohm impedance for voltage circuit.

* Built-in overload protection for most ranges.

* LSI circuit provides high reliability and durability.

* Uses durable, long-lasting components, enclosed in strong, light weight ABS-plastic housing.

* Full line optional adapters : Clamp adapter, Tachometer adapter, Pressure adapter, Humidity Adapter, Sound level adapter, Anemometer adapter, Light adapter, EMF adapter.

 

GENERAL SPECIFICATIONS

Display

39.5 mm x29.8 mm large LCD display

Measurement

DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Diode, Continuity beeper, Temperature.

A/D counts no.

6000 counts.

Smart function

" V " function can select ACV, DCV automatically with auto range.

" Ω " function can select the Resistance, Diode, Continuity beeper, Capacitance automatically with auto range.

"600A " " 1000A " function can measure ACA, DCA .

MAX./MIN.

Records Maximum & Minimum readings with recall.

Data hold

To freeze the display reading on the LCD display

Power On/Off management

Auto power of or manual power off.

Hz button

When execute the voltage or current function also can measure the frequency of signal.

Selection Range

Smart function or auto function . 

manual range selecting.

Polarity

Automatic Switching, " - " indicates negative polarity.

Sampling time

Approx. 0.5 to 1 second.

Operating Temperature

0 to 50 (32 to 122 )

Operating Humidity

Max. 80% RH.

Power supply

DC 9 V battery

006P,MN1604

Power consumption

Approx. DC 9.1 mA.

Max. Conductor Size

32 mm (1.3 inch) Dia..

Dimension

241 x94 x 46 mm ( 9.5 x 3.7 x 1.8 inch ).

Weight

384 g/0.95 LB ( w/o battery ).

Accessories Included

* Red and Black Test Leads.......... 1 Set

* Instruction Manual.................... 1 PC

* Soft carrying case .................... 1 PC

Optional type K Temp. probe

TP-01, TP-02A, TP-03, TP-04, TP-05A

Optional Accessories

Full line adapters :

ACA/DCA current adapter,

Tachometer adapter,

Humidity adapter, Pressure adapter,

Light adapter, EMF adapter,

Sound level adapter,

High voltage probe.

 

ELECTRICAL SPECIFICATIONS (23±5 )

50588256fa0de279e92b1b662a706052.png

10fe43e075ac88a97dbe3646a9ad3057.png