CP-6001 6,000A FLEXIBLE CURRENT PROBE
60 A/600 A/6000 A, 3 ACV at full scale, probe length 900 mm
CP-6001 an cooperate any kinds multimeters ( ACmV meters )
6,000A FLEXIBLE CURRENT PROBE
Model : CP-6001 ISO-9001, CE, IEC1010
FEATURES
* Range : 60 A/600 A/6000 A. |
* Output sensitivity : 50 mV/A, 5 mV/A, 0.5 mV/A. |
* Output voltage : 3 ACV ( 60 A, 600 A, 6000 A ). |
* Flexible probe length : 900 mm ( 35.4 inch ). |
* Optional current probe for DW-6093, DW-6095. |
* When change the new probe, the calibration procedures are not necessary to be executed. |
* Signal output use the banana plugs, durable and safety. |
* Power supply is from DC 1.5 V, AA ( UM-3 ) battery x 2 PCs or from the optional AC to DC 9V adapter. or from the meter (DW-6093, DW-6095 ) via Power interface cable, PWCB-06. |
SPECIFICATIONS
Measurement ranges | 60 A/600 A/6000 A, 3 ranges, switch selectable 1st range value : 60 A 2nd range value : 600 A 3rd range value : 6000 A |
Output sensitivity | 50 mV/A, 5 mV/A, 0.5 mV/A, AC coupled. |
Accuracy | ± 1% of range value * Accuracy is specified that the measured conductor's position is on the center of " Flexible current probe ". * 50/60 Hz. * 23 ± 5 ℃ |
Frequency range | 45 to 400 Hz. * Accuracy tested under 50/60 Hz. |
Linearity | ± 0.2 % of reading value from 10 % to 100% of range value. |
Phase error | ± 1.5° * 50/60 Hz. |
Conductor position sensitivity | ± 2 % of range value. * Recommend the measured conductor position should > 25 mm ( 1" ) away from the " Probe locker ". |
External field influence | increase ± 1.5 % of range value max.. * Recommend the distance between different " Flexible current probe " should > 200 mm ( 8" ). |
Minimum load | 100 K ohm for specified accuracy. |
Enclosure material | UL 94-V0 rated. |
Safety | IEC 1010, Categories III 600V. |
Power Supply | 1 DC 1.5 V, AA ( UM-3 ) battery x 2 PCs 2 AC to DC 9V power adapter ( optional ). 3 Power supply from the meter ( DW-6093, DW-6095 ) via Power interface cable, PWCB-06 ( included ). * Power supply voltage from DW-6093, DW-6095 is DC 8V± 1V. |
OperatingTemperature | 0 ℃ to 50 ℃( 32 ℉ to 122 ℉). |
Operating Humidity | Less than 80% RH. |
Dimension | Main circuit unit : 105 x 56.5 x 33 mm. ( 4.1 x 2.2 x 1.3 inch ). Flexible probe : 900 mm x 14.5 mm DIA. 35.4 inch x 0.57 inch DIA. Cable length : 3.3 meters ( 10.8 feet ). DC plug size : 5.5 mm x 2.5 mm DIA. |
Power Consumption | Approx DC 9 mA. |
Weight | 523 g ( 1.2 LB ). |
Accessory Included | Operating manual ...........................1 PC. Power interface cable, PWCB-06.......1 PC. |
Optional Accessory | AC to DC 9V power adapter. |
FRONT PANEL DESCRIPTIONS