CWF-3300 FLEXIBLE AC POWER METER

True rms, 3000 A

FLEXIBLE AC POWER METER

Model : CWF-3300                                       ISO-9001, CE, IEC1010

b44b42c07b78d17cd41e3852cdfbfe1c.png

FEATURES

* Meet IEC 1010 CAT III 1000 V safety requirement.

* 6000 counts A/D, high resolution.

* Double insulation coil.

* Voltage and Current are the True RMS value.

* ACV input impedance is 10 Mega ohms.

* True Power(KW) measurement.

* Apparent Power (KVA) measurement.

* Reactive Power (KVAR) measurement.

* Power Factor (PF) measurement.

* Voltage measurement range: 10 to 600 ACV.

* Current measurement range: 1 to 3000 ACA.

* Resistance measurement range: 20 KΩ

* Data hold .

* Auto shut off is available to save battery life.

* Safety Standard : IEC 1010, CAT IV 600V.

* Powered by AAA ( UM-4 ) DC 1.5 V X 2 batteries

* Built-in overload protection for most ranges.

* LSI circuit provides high reliability and durability.

* Uses durable, long-lasting components, enclosed in strong, light weight ABS-plastic housing.

GENERAL SPECIFICATIONS 

Display

33.5 mm x18.7 mm  LCD display

Measurement

ACV,  ACA, KW , KVA ,  KVAR ,  PF Resistance, Continuity beeper

A/D counts no.

6000 counts.

Function

 *" WATT " function can select  : ACV, ACA, KW , KVA ,  KVAR ,  PF

 *" Ω " function can select : Resistance , Continuity beeper

Data hold

To freeze the display reading on the LCD display.

Power On/Off management

Auto power off or manual power off.

Selection

Select (ACV, ACA, KW , KVA ,  KVAR ,  PF )Function .

Polarity

Appears when measuring a PF value negative Capacitive loads are leading

(current leads voltage)

Sampling time

Approx. 0.5 to 1 second.

Operating Temp.

to 50 (32 to 122 )   

Operating humidity

Max. 80% RH.

Power supply

DC 1.5 V battery ( UM-4, AAA ) x 2

Power consumption

Approx. DC 25 mA.

Flexible Cable length

300 mm

Flexible Cable Diameter

8 mm

Dimension

290 x135 x 27.8 mm ( 11.4x 5.3 x 1.09 inch ).

Weight

208 g/0.46 LB ( w.o battery ).

Accessories Included

Red and Black Test Leads................ 1 Set

Instruction Manual........................... 1 PC

 

ELECTRICAL SPECIFICATIONS (23±5  

 

AC Voltage ( True rms ) 

Range

10 to 600 V

Resolution

0.1V

Accuracy

± ( 0.5% + 5d )

* Spec. are tested under 50/60 Hz.

Input impedance

10 M ohm.

Over load protection

750 ACV

 

AC Current ( True rms ) 

Range

999.9A/3000A

Resolution

0.1A /1A

Accuracy

1000 A Range

± ( 1% +8d )

3000 A Range

± ( 1% +10d )

Linearity

± 0.2% of reading value

* From 10 % to 100 % of range value.

Conductor position sensitivity

± ( 2% +15d ) of reading value

* The measured conductor distance from center > 25mm (1" )

External field influence

Increase ± 1.5% of range value max.

*Recommend the distance between different " Flexible current probe "  should > 200mm

Remark

*Accuracy is specified that the measured conductor's position is on the center of "Flexible current probe".

*ACA specification be tested on sine wave 50/60 Hz.

*Measurement range:1A to 3000A

 

Active / Apparent / Reactive ( W/VA/VAR ) 

Range

999.9/9.999K/99.99K/999.9K/1800K (W / VA / VAR)

Resolution

0.1 / 0.001K / 0.01K / 0.1K / 1K (W / VA / VAR)

Accuracy

± (1.5% +20d )

*Spec. are tested under 50/60 Hz.

*Spec. are specified under following condition :

PF 0.1 to 1.0 , PT = 1, ACV >10V, ACA > 5 A

 

Power factor 

Range

0.00 to 1.00

Resolution

0.01

Accuracy

± 0.04

Remark

*Spec. are specified under following condition : ACV > 10V, ACA > 5 A

 

OHMS 

Range

20 KΩ

Resolution

0.01 KΩ

Accuracy

± ( 1.5 % + 5d )

Over load protection

± 350 DCV, 350 ACV.

 

Continuity Beeper 

Beeper will sound if measured resistance less than 20 ohm.

 