DM-9862 MULTIMETER + LCR
Inductance, Capacitance, + Temp., 6,000 counts
RS232/USB computer interface
MULTIMETER + LCR
Model : DM-9862 ISO-9001, CE, IEC1010
FEATURES
* Meet IEC 1010 CAT III 1000 V safety requirement. |
* LCD with green light backlight, easy reading. |
* 6000 counts A/D, high resolution. |
* Multi function measurement. DCV, ACV, DCA, ACA, Resistance, Capacitance, Inductance, Frequency, Temperature, Diode, Continuity beeper. |
* Max. & Min. measurement value with recall. |
* Relative, Data hold. |
* Auto range with manual range selection. |
* Temperature measurement possibility. |
* VAHz button, when execute the ACV, ACA function also can measure the frequency of signal. |
* Both 10 A, mA, uA current are build fuse for safety consideration. |
* 10 M ohm impedance for voltage circuit. |
* Operates from 9 V ( 006P, MIN1604 ) batteries. |
* Built-in overload protection for most ranges. |
* Photo couple RS 232 computer serial interface. |
* Uses durable, long-lasting components, enclosed in strong, light weight ABS-plastic housing. |
* Full line optional adapters : Clamp adapter, Tachometer adapter, Pressure adapter, Humidity Adapter, Sound level adapter, Anemometer adapter, Light adapter, EMF adapter. |
GENERAL SPECIFICATIONS
Display | 60 mm x 39.5 mm large LCD display |
Measurement | DCV, ACV, DCA, ACA, Resistance, Diode, Continuity beeper, Capacitance, Inductance, Frequency, Temperature. |
A/D counts no. | 6000 counts. |
Range selection | Auto range with manual range selecting. |
Special function | Relative measurement, Data hold, |
Data hold | To freeze the display reading on the LCD display. |
Power On/Off management | Auto power of or manual power off. |
Memory recall | Records Maximum & Minimum readings with recall. |
Relative measurement | To offset the measurement value. |
VAHz button | When execute the voltage or current function also can measure the frequency of signal. |
Data output | RS 232 PC serial interface, photo couple. |
Polarity | Automatic Switching, " - " indicates negative polarity. |
Zero adjustment | Automatic. |
Sampling time | Approx. 0.5 to 1 second. |
Operating Temp. & humidity | 0 ℃ to 50 ℃ (32 ℉ to 122 ℉), Max. 80% RH. |
Power supply | 9 V ( 006P, MIN1604 ) DC 9V adapter input * AC/DC Power adapter is optional. |
Power consumption | Approx. DC 5.5 mA. |
Dimension | 190 x 88 x 40 mm ( 7.5 x 3.5 x 1.6 inch ). |
Weight | 378 g/0.83 LB ( w/o battery ). |
Accessories Included | Red and Black Test Leads ( CAT III 1KV Test Leads )...............1 Set 0.63 Amp Spare Fuse.......................1 PC Instruction Manual...........................1 PC |
Optional accessories | * Full line adapters : ACA/DCA current adapter, Pressure adapter, Light adapter, EMF adapter, Sound level adapter, High voltage probe. * AC to DC 9V adapter................. AP-9VA * Hoster......................................HS-03 * Type K Temperature probe........ TP-11 * Soft carrying case..................... CA-05A * RS232 cable............................. UPCB-06 |
ELECTRICAL SPECIFICATIONS (23±5 ℃)
DC Voltage
Range | 600.0 mV /6 V/60 V/600 V /1000 V | |
Resolution | 0.1 mV /0.001V /0.01V /0.1V/1 V | |
Accuracy | ± ( 0.5% + 2d ) | 600 mV |
± ( 0.8% + 1d ) | 6 V, 60 V, 600 V, 1000 V | |
Input impedance | 10 M ohm. | |
Over load protection | 600 mV range | ± 50 DCV, 50 ACV |
other ranges | ± 1000 DCV, 1000 ACV |