LX-1102 LIGHT METER
LIGHT METER
Model : LX-1102 ISO-9001, CE, IEC1010
FEATURES
* 5 ranges : 40.00/400.0/4,000/40,000/400,000 Lux, wide measuring range.
* High resolution : 0.01 Lux to 100 Lux, 0.01 Ft-cd to 10 Ft-cd
* Sensor used the exclusive photo diode & color correction filter, spectrum meet C.I.E. photopic.
* Sensor cosine correction factor meet standard.
* Separate Light Sensor allows user to measure the light at an optimum position.
* Lux & Foot-candle unit selection.
* Large LCD display with bargraph and indicator.
* Water resistance front panel
* Use the rubber key for the function select.
* LSI circuit provides high reliability and durability.
* Zero adjusting button.
* Data hold.
* Memory function to display the max. & min. display value with Recall.
* Auto power auto off or manual power off.
* Compact size and excellent operation.
* Built-in low battery indicator.
* RS-232 computer serial data output.
GENERAL SPECIFICATIONS | |||
Display | Large LCD dispaly. LCD size 52 x 38 mm, 4 digits. with bargraph indicator | Operating Temperature | 0 to 50 ℃ ( 32 to 122 ℉ ). |
Measurement & ranges | 5 ranges : 40.00/400.0 Lux 4,000/40,000/400,000Lux, | Operating Humidity | Max. 80% RH. |
Unit
| Lux, Foot-candle ( Ft-cd ).
| Power Supply
| DC 9V battery. 006P, MN1604 ( PP3 ) or equivalent. |
Sensor
| The exclusive photo diode & color correction filter, spectrum meet C.I.E. Cosine correction factor meet standard. | Power Consumption
| Approx. DC 8 mA.
|
Zero Adjustment
| External adjustment by pushing button. ( 40.00 Lux range only | Weight
| 220 g/0.48 LB.
|
Peak Hold
| To hold the peak display.
| Dimension
| Main instrument : 200 x 68 x 30 mm ( 7.9 x 2.7 x 1.2 inch ). Sensor probe : 82 x 55 x 7 mm ( 3.2 x 2.2 x 0.3 inch ). |
Data Hold | To freeze the display value. | ||
Memory
| Save the max. & min. value with Recall | Accessories Included
| Instruction Manual.......1 PC. Light Sensor with protection cover..........................1 PC.
|
Over and Under range Indication | Over range Indicator : "- - - - " | ||
Under range Indicator : "_ _ _ _ " | Optional Accessories
| RS232 cable, UPCB-02 USB cable, USB-01 Application Software, SW-U801-WIN Hard carryingt case, CA-06 Soft carryingt case, CA-05A | |
Power Off | Auto or manaual power off. | ||
Data Output | RS-232 serial data output. |
ELECTRICAL SPECIFICATIONS ( 23±5 ℃ ) | ||||
Measurement | Range | In - range Display | Resolution | Accuracy |
Lux
| 40.00 Lux | 0 - 40.00 Lux | 0.01 Lux | ± ( 3% rdg + 0.5 % F.S.. )
|
400.0 Lux | 36.0 - 400.0 Lux | 0.1 Lux | ||
4,000 Lux | 360 - 4,000 Lux | 1 Lux | ||
40,000 Lux | 3,600 - 40,000 Lux | 10 Lux | ||
400,000 Lux | 10,000 - 400,000 Lux | 100 Lux | < 100,000 Lux : ± ( 3% rdg + 0.5 % F.S.. ) ≥ 100,000 Lux : @ for refereence only | |
Foot-candle ( Fc )
| 4.000 Fc | 0 - 3.720 Fc | 0.001 Fc | ± ( 3% rdg + 0.5 % F.S.. )
|
40.00 Fc | 3.35 - 37.20 Fc | 0.01 Fc | ||
400.0 Fc | 33.5 - 372.0 Fc | 0.1 Fc | ||
4,000 Fc | 335 - 3,720 Fc | 1 Fc | ||
40,000 Fc | 930 - 37,200 Fc | 10 Fc | < 9,300 Fc : ± ( 3% rdg + 0.5 % F.S.. ) ≥9,300 Fc @ for refereence only | |
Note : Accuracy tested by a standard parallel light tungsten lamp of 2856 K degree temperature. |