LX-1102 LIGHT METER

LIGHT METER 

Model : LX-1102             ISO-9001, CE, IEC1010
304a4876fef19d31bf64a73ad901828d.png

 FEATURES

* 5 ranges : 40.00/400.0/4,000/40,000/400,000 Lux, wide measuring range. 

* High resolution :  0.01 Lux to 100 Lux, 0.01 Ft-cd to 10 Ft-cd 

* Sensor used the exclusive photo diode & color correction filter, spectrum meet C.I.E. photopic. 

* Sensor cosine correction factor meet  standard. 

* Separate Light Sensor allows user to  measure the light at an optimum position. 

* Lux & Foot-candle unit selection.

* Large LCD display with bargraph and  indicator.

* Water resistance front panel 

* Use the rubber key for the function select.

* LSI circuit provides high reliability and durability.

* Zero adjusting  button. 

* Data hold. 

* Memory function to display the max. & min. display value with Recall.

* Auto power auto off or manual power off.

* Compact size and excellent operation.

* Built-in low battery indicator.

* RS-232 computer serial data output.

 

GENERAL SPECIFICATIONS 

Display

Large LCD dispaly. 

LCD size 52 x 38 mm, 4 digits. 

with bargraph indicator

Operating

Temperature

0 to 50  ( 32  to 122  ). 

Measurement

& ranges 

5 ranges : 40.00/400.0 Lux

4,000/40,000/400,000Lux, 

Operating

Humidity

Max. 80% RH.

Unit

 

 

Lux, Foot-candle ( Ft-cd ). 

 

 

Power Supply 

 

DC 9V battery. 006P,

MN1604 ( PP3 ) or equivalent. 

Sensor

 

 

 

 

The exclusive photo diode & color correction filter, spectrum meet C.I.E. Cosine correction 

factor meet standard. 

Power

Consumption

 

 

 

 

Approx. DC 8 mA. 

 

 

 

Zero

Adjustment

 

External adjustment by 

pushing button.

( 40.00 Lux range only 

Weight

 

 

220 g/0.48 LB. 

 

 

 

Peak Hold

 

 

 

 

 

To hold the peak display.

 

 

 

Dimension

 

 

 

 

 

 

 

Main instrument :

200 x 68 x 30 mm 

( 7.9 x 2.7 x 1.2 inch ). 

Sensor probe : 

82 x 55 x 7 mm 

( 3.2 x 2.2 x 0.3 inch ). 

Data Hold 

To freeze the display value.

Memory

 

 

Save the max. & min. value 

with Recall

Accessories

Included

 

 

 

 

 

Instruction Manual.......1 PC.

Light Sensor with protection 

cover..........................1 PC.

 

Over and 

Under range 

Indication

Over range Indicator : 

"- - - - " 

Under range Indicator : 

"_ _ _ _ " 

Optional

Accessories 

 

 

 

 

RS232 cable, UPCB-02

USB cable, USB-01

Application Software, 

SW-U801-WIN

Hard carryingt case, CA-06 

Soft carryingt case, CA-05A

Power Off 

Auto or manaual power off. 

Data Output 

RS-232 serial data output.

 

 ELECTRICAL SPECIFICATIONS ( 23±5   )

Measurement 

Range 

In - range Display 

Resolution 

Accuracy 

Lux

 

 

 

40.00 Lux 

0 - 40.00 Lux 

0.01 Lux 

 ± ( 3% rdg + 0.5 %  F.S.. ) 

 

400.0 Lux 

36.0 - 400.0 Lux 

0.1 Lux 

4,000 Lux 

360 - 4,000 Lux 

1 Lux 

40,000 Lux 

3,600 - 40,000 Lux 

10 Lux 

400,000 Lux 

10,000 - 400,000 Lux

100 Lux 

< 100,000 Lux : 

 ± ( 3% rdg + 0.5 %  F.S.. ) 

≥ 100,000 Lux :

   @ for refereence only

Foot-candle 

 ( Fc ) 

 

 

4.000 Fc 

0 - 3.720 Fc 

0.001 Fc 

 ± ( 3% rdg + 0.5 %  F.S.. ) 

 

40.00 Fc 

3.35 - 37.20 Fc 

0.01 Fc 

400.0 Fc 

33.5 - 372.0 Fc 

0.1 Fc 

4,000 Fc 

335 - 3,720  Fc 

 1 Fc 

40,000 Fc 

930 - 37,200 Fc 

10 Fc 

<   9,300 Fc :

  ± ( 3% rdg + 0.5 %  F.S.. )

≥9,300 Fc 

  @ for refereence only
 

 Note : Accuracy tested by a standard parallel light tungsten lamp of 2856 K degree  temperature.