首頁
1
商品介紹
2
GTCL-PS(P+S Wave) Earthquake Early Warning Sensor3
https://www.gtcl.url.tw/ 格創科技有限公司
首頁 商品介紹 震動設備產品系列 GTCL-PS(P+S Wave) Earthquake Early Warning Sensor
1284

GTCL-PS(P+S Wave) Earthquake Early Warning Sensor

Earthquake Early Warning Sensor

(P Wave + S Wave)


7dad3c7ad3956219a5b9d76cbf050003.png

Function

This product is used for early earthquake warning and earthquake (vibration) monitoring. It can complete the earthquake early warning assessment by monitoring the pre-seismic guided waves (P wave, vertical ground direction, Y direction of this product). Simultaneously monitor the seismic damage wave (S wave, parallel ground direction, X-Z direction of this product) to achieve the function of earthquake protection. The liquid crystal (LCD) panel can display three axis (x, y, z) acceleration values (gal), combined vector acceleration values (gal), and corresponding seismic intensity of the Central Weather Bureau(CWB). In addition, you can also set the trigger value through the DIP switch for activating relays. Moreover, built-in rechargeable battery can support emergency power for several hours.

 

Setting:

841db49466562d4cbb561d6d64158994.png

Relay 1:

Monitoring of guided waves before the earthquake (P wave, vertical ground direction, Y direction of this product) (5 ~ 10gal). Within 30 seconds after the relay 1 is triggered, if there is not a sufficiently large S wave (S Low1), the relay 1 will automatically reset (reset).

6ed7a6d26b101ddef532949983784959.png

Relay 2:

Monitoring of seismic damage waves (S wave, parallel ground direction, X-Z direction of this product). Relay 2 can be set to trigger value via DIP switch: S Low1: 20, 50, or 80 (gal).

0af87e4e11e6816002e909f1a1f58ce8.png

Relay 3:

Monitoring of seismic damage waves (S wave, parallel ground direction, X-Z direction of this product). Relay 3 can be set to trigger value via DIP switch: S Low2: 120 or 150 (gal).

ed95b98218d9d457419d2a63c69b68ee.png

Relay 4:

Monitoring of seismic damage waves (S wave, parallel ground direction, X-Z direction of this product). Relay 4 has been set at the factory. Please tell me how many gals to set. The default value is S HIGH: 150 gal.

4f1e9f1f232e2278de147e611f421e93.png

Features:

 

1. This product is used for early earthquake warning and earthquake (vibration) monitoring. It can complete the earthquake early warning assessment by monitoring the pre-seismic guided waves (P wave, vertical ground direction, Y direction of this product). Simultaneously monitor the seismic damage wave (S wave, parallel ground direction, X-Z direction of this product) to achieve the function of earthquake protection device.

2. Easy installation and position (Y axis needs to be vertical to the ground plane). The system will automatically calibrate after power on.

3. LCD Display real-time 3-axis seismic acceleration value (gal).

4. LCD Display real-time earthquake (seismic) intensity, providing information to us (ex: security guards, researcher …).

5. Built-in high brightness LED. (Lighting for people evacuating at night while earthquake happen)

6. Built-in rechargeable battery, with UPS function. (Backup electricity for power failure due to earthquake)

7. Voice alarm. (English, Chinese, ..)

8. Four triggers. (P,S Low1,S Low2,S High)

9. Calibrated before shipping.

10. Operation temperature: -10 ~ 60.(Suggest not exceed 50 if within battery)

11. Build-in fuse.

 

Spec

Supply Voltage

DC 24V

Operating Voltage

DC 14 V ~ DC 25 V

Rechargeable battery

8.4 V;850 mA

Size

18.4 cm*11.0 cm*4.0 cm

Weight

~600 g

Operation temperature

-10~ 60

 

Outline:

8dac2d41951a2221a8869d53a22dc696.png

1374998