LCR-9063 POCKET DIGITAL LCR METER
POCKET DIGITAL LCR METER
Model : LCR-9063 ISO-9001, CE, IEC1010
FEATURES
* A pocket, Battery operated, Inductance, Capacitance and Resistance Meter. * LSI-circuit provides high reliability and durability. * LCD display for clear readout even in bright ambient * Ilight conditions. * Rotary switch function selector. * Color-coded panel for easy indentification of functions and ranges. * Low battery indicator. |
GENERAL SPECIFICATIONS
Display | 13 mm (0.5") LCD, 3 1/2 digits. Max. reading 1999. |
Over-input indicator | " 1 " mark indication. |
Sampling Time | Approx. 0.4 second. |
Operating Temp. | 0 to 50℃ (32 to 122℉). |
Operating Humidity | Less than 80% RH. |
Power Supply | 006 P DC 9V battery, heavy duty battery. |
Dimensions | 120 x 72 x 37 mm . |
Weight | 185 g/0.41 LB. |
Power Consumption | R - Approx. 8 mA. L - Approx. 9 mA. C - Approx. 9 mA. |
Accessories Included | Instruction Manual .................1 PC Test alligator clips ..................1 pair |
ELECTRICAL SPECIFICATIONS ( 23±5℃)
Range | In-range Display | Resolution | Test Frequency | Accuracy |
* 2 mH | 0.02 mH-2 mH | 1 uH | 250 Hz | ± (3 % + 3 d) |
20 mH | 2 mH-20 mH | 10 uH | 250 Hz | |
200 mH | 20 mH-200 mH | 100 uH | 250 Hz | |
2 H | 0.2 H-2 H | 1 mH | 250 Hz | ± (5 % + 5 d) |
20 H | 2 H-20 H | 10 mH | 250 Hz | |
uH = micro Henry (10^-6 H). mH = mili Henry (10^-3 H). * Zero stray inductance of 2 mH range (short ckt.) : 0 to -30 uH. |
Range | In-range Display | Resolution | Test Frequency | Accuracy |
* 2 nF | 10 pF-2 nF | 1 pF | 250 Hz | ± (3 % + 3 d) |
20 nF | 200 pF-20 nF | 10 pF | 250 Hz | |
200 nF | 2 nF - 200 nF | 100 pF | 250 Hz | |
2 uF | .02 uF - 2 uF | 1 nF | 250 Hz | |
20 uF | 0.2 uF - 20 uF | 10 nF | 250 Hz | |
200 uF | 2 uF - 200 uf | 100 nF | 250 Hz | |
pF= pico Farad (10^-12 F) nF= nano Farad (10^-9 F) uF= micro Farad (10^-6 F) * Zero stray capacitance of 2 nF range (open ckt.) : 30 pF |
Range | Resolution | Open Circuit Voltage | Accuracy |
200 ohm | 0.1 ohm | Approx. 600 mV | ± ( 2 % + 3 d ) |
2 k | 1 ohm | ||
20 k | 10 ohm | ||
200 k | 100 ohm | ||
2000 k | 1 k | ||
20 M | 10 k | Approx. 300 mV |
Remark : Though the internal test frequency is approx. 250 Hz. However the accuracy adjustment are executed as : * For the capacitance ( 2 uF, 200 nF, 20 nF, 2 nF ) range ,the acuracy adjustment is compared with the " Standard capacitor that tested under the 1 KHz frequency ". * For the capacitance ( 20 uF, 200 uF ) range, the accuracy adjustment is compared with the " Standard capacitor that tested on the 100 Hz frequency ". * For the inductance ( 2 mH , 20 mH , 200 mH , 2 H ) range , the accuracy adjustment is compared the " Standard inductor that tested on the 1 KHz ". * For the inductance ( 20 H ) range , the calibration is compared the " Standard inductor that tested on the 100 Hz ". |