首頁
1
商品介紹
2
PPS-9312 PRESSURE CONTROLLER/MONITOR3
https://www.gtcl.url.tw/ 格創科技有限公司
首頁 商品介紹 PRESSURE METER PPS-9312 PRESSURE CONTROLLER/MONITOR
1200

PPS-9312 PRESSURE CONTROLLER/MONITOR

2, 5, 10, 20, 50, 100, 400 bar
PRESSURE
CONTROLLER/MONITOR
Model : PPS-9312                     ISO-9001, CE, IEC1010

a6758172eec1ecfd1175bb81034e2d81.png

FEATURES

  • Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary typically when change a new sensor .
  • Unit select : Bar, PSI, Kg/cm^2, inch Hg, mm Hg, inch H2O, meter H2O, Atmosphere, hPa, KPa.
  • Large red LED display, high brightness and easy to read.
  • Control setting, Hi/Lo alarm setting.
  • Control relay output, alarm relay output.
  • Alarm Relay will make action when the reading value reach to high/low alarm value.
  • Control Relay will make action when the reading value reach to control value.
  • Hysteresis value setting for control and alarm function.
  • Microprocessor circuit ensures high accuracy and provides special functions and features.
  • Power : 90 ACV to 264 ACV, 50/60 Hz.
  • Cooperate the 4-20 mA pressure input, sensor can install in the faraway position.
  • DC 12V output, used for the power of pressure sensor.
  • RS-232/USB computer interface.
  • DIN size : 96 x 48 mm. Depth : 107 mm.
  • Optional pressure sensor, TR-PS2W-xxBAR, PS93MA-xxBAR.
  • Optional USB cable, USB-01.
  • Optional data acquisition software.
  • Optional GSM controller.

GENERAL SPECIFICATIONS

Display

4 digits red LED, digit size : 14 mm.x 10, x100 indicator

Circuit

Custom chip of microprocessor LSI circuit.

Sensor type

Can cooperate with optional 2, 5, 10, 20, 50, 100, 200, 400 bar two wires 4 to 20 mA pressure sensor, new calibration are not necessary typically when change the new sensor .

* Sensor type can make the internal setting with default

Display units

Bar, Psi, Kg/cm^2, mm Hg, inch Hg, meter H2O, inch H2O, Atmosphere, hPa, KPa.

* Unit can make the internal setting with default

Accuracy

± ( 0.5% + 2 d )

* Meter only.

* Within 23 ± 5 

Pressure sensor

* optional

Cooperate the optional two wires ( or four wires ) 4 to 20 mA pressure sensors ( transmitters ).

* two wires sensor : TR-PS2W-xxBAR

* Four wires sensor : PS93MA-xxBAR

Offset adjust

It can make the internal Offset setting with default.

Gain adjust

It can make the internal Gain setting with default.

Input signal from sensor

* Input 4 mA = 0 pressure

* Input 20 mA = full scale pressure

Sampling Time

Approx. 1 second.

Relay Output

Number

2 relays

Function

Relay 1 :

Control relay.

Relay 2 :

High/Low alarm relay.

Max load

 4abf61e7d444da8c49a01b6ec079b339.png

0.5 ACA/250 ACV

0.5 DCA/24 DCV

* Do not apply the relay contact load current > 0.5 A, other wise the relay may be damaged permanently without warranty.

Setting Function

1st layer setting procedures

CtLo ( Control low limit )

CtHi ( Control high limit )

ALLo ( Alarm low limit )

ALHi ( Alarm high limit )

Second layer setting procedures

tyPE ( Sensor type )

FiLt ( Digital filter )

CtHy ( Control hysteresis set )

ALHy ( Alarm hysteresis set )

oFSt ( Offset adjustment )

GAin ( Gain adjustment )

Unit ( Unit set )

External Power Supply

DC 12 V, 50 mA max.

Data Output

RS 232 PC serial interface.

Operating Temperature

0 to 50 .

Operating Humidity

Less than 80% R.H.

Power Supply

90 to 260 ACV, 50/60 Hz.

Power Consumption

Approx. 5.3 VA/AC 110V.

Approx. 7.3 VA/AC 220V.

Weight

384 g/ 0.84 LB.

Dimension

DIN size : 96 x 48 mm.

Depth : 110 mm.

Accessories Included

Instruction manual..............................1 PC

Case holder with screw........................2 PCs

Optional Accessories

Two wires pressure transmitters,

Model : TR-PS2W-xx BAR

* Range : 2, 5, 10, 20, 50, 100, 400 BAR.

* Data Acquisition software, SW-U801-WIN.

* RS232 cable, UPCB-02.

* USB cable, USB-01.

* Real time SD card datalogger DL-9602SD

* GSM controller, GSM-889.

* Interface cable ( cable between meter to GSM-889 ), GMCB-89.

1370361