PPS-9312 PRESSURE CONTROLLER/MONITOR
2, 5, 10, 20, 50, 100, 400 bar
PRESSURE
CONTROLLER/MONITOR
Model : PPS-9312 ISO-9001, CE, IEC1010
FEATURES
- Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary typically when change a new sensor .
- Unit select : Bar, PSI, Kg/cm^2, inch Hg, mm Hg, inch H2O, meter H2O, Atmosphere, hPa, KPa.
- Large red LED display, high brightness and easy to read.
- Control setting, Hi/Lo alarm setting.
- Control relay output, alarm relay output.
- Alarm Relay will make action when the reading value reach to high/low alarm value.
- Control Relay will make action when the reading value reach to control value.
- Hysteresis value setting for control and alarm function.
- Microprocessor circuit ensures high accuracy and provides special functions and features.
- Power : 90 ACV to 264 ACV, 50/60 Hz.
- Cooperate the 4-20 mA pressure input, sensor can install in the faraway position.
- DC 12V output, used for the power of pressure sensor.
- RS-232/USB computer interface.
- DIN size : 96 x 48 mm. Depth : 107 mm.
- Optional pressure sensor, TR-PS2W-xxBAR, PS93MA-xxBAR.
- Optional USB cable, USB-01.
- Optional data acquisition software.
- Optional GSM controller.
GENERAL SPECIFICATIONS | |||
Display | 4 digits red LED, digit size : 14 mm.x 10, x100 indicator | ||
Circuit | Custom chip of microprocessor LSI circuit. | ||
Sensor type | Can cooperate with optional 2, 5, 10, 20, 50, 100, 200, 400 bar two wires 4 to 20 mA pressure sensor, new calibration are not necessary typically when change the new sensor . * Sensor type can make the internal setting with default | ||
Display units | Bar, Psi, Kg/cm^2, mm Hg, inch Hg, meter H2O, inch H2O, Atmosphere, hPa, KPa. * Unit can make the internal setting with default | ||
Accuracy | ± ( 0.5% + 2 d ) * Meter only. * Within 23 ℃± 5 ℃ | ||
Pressure sensor * optional | Cooperate the optional two wires ( or four wires ) 4 to 20 mA pressure sensors ( transmitters ). * two wires sensor : TR-PS2W-xxBAR * Four wires sensor : PS93MA-xxBAR | ||
Offset adjust | It can make the internal Offset setting with default. | ||
Gain adjust | It can make the internal Gain setting with default. | ||
Input signal from sensor | * Input 4 mA = 0 pressure * Input 20 mA = full scale pressure | ||
Sampling Time | Approx. 1 second. | ||
Relay Output | Number | 2 relays | |
Function | Relay 1 : Control relay. | ||
Relay 2 : High/Low alarm relay. | |||
Max load
| 0.5 ACA/250 ACV 0.5 DCA/24 DCV * Do not apply the relay contact load current > 0.5 A, other wise the relay may be damaged permanently without warranty. | ||
Setting Function | 1st layer setting procedures | CtLo ( Control low limit ) CtHi ( Control high limit ) ALLo ( Alarm low limit ) ALHi ( Alarm high limit ) | |
Second layer setting procedures | tyPE ( Sensor type ) FiLt ( Digital filter ) CtHy ( Control hysteresis set ) ALHy ( Alarm hysteresis set ) oFSt ( Offset adjustment ) GAin ( Gain adjustment ) Unit ( Unit set ) | ||
External Power Supply | DC 12 V, 50 mA max. | ||
Data Output | RS 232 PC serial interface. | ||
Operating Temperature | 0 to 50 ℃. | ||
Operating Humidity | Less than 80% R.H. | ||
Power Supply | 90 to 260 ACV, 50/60 Hz. | ||
Power Consumption | Approx. 5.3 VA/AC 110V. Approx. 7.3 VA/AC 220V. | ||
Weight | 384 g/ 0.84 LB. | ||
Dimension | DIN size : 96 x 48 mm. Depth : 110 mm. | ||
Accessories Included | Instruction manual..............................1 PC Case holder with screw........................2 PCs | ||
Optional Accessories | Two wires pressure transmitters, Model : TR-PS2W-xx BAR * Range : 2, 5, 10, 20, 50, 100, 400 BAR. | ||
* Data Acquisition software, SW-U801-WIN. * RS232 cable, UPCB-02. * USB cable, USB-01. | |||
* Real time SD card datalogger DL-9602SD | |||
* GSM controller, GSM-889. * Interface cable ( cable between meter to GSM-889 ), GMCB-89. | |||